下载文件详细资料 | |
文件名称: | GPIB ENET 100 使用说明 |
公司名称: | 深圳市汉润电子有限公司 |
下载次数: | 358 |
文件详细说明: | |
Overview Ethernet ports are a standard feature oftoday’s computers.Most of these computers have operating systems with built-in TCP/IP network software capability.The National Instruments GPIB-ENET/100 Ethernet-to-GPIB controller and NI-488.2 take advantage ofthis network connectivity in instrument control applications.Using the NI GPIB-ENET/100,networked computers can communicate with and control IEEE 488 devices from anywhere on an Ethernet-based TCP/IP network.You can use a GPIB-ENET/100 to share a single GPIB system among many networked users or to control several test systems from a single networked host computer. NI-488.2 for the GPIB-ENET/100 is available for a variety of operating systems.You can port application programs written for other National Instruments GPIB interfaces for use with the GPIB-ENET/100,without modifying the code.Additionally,you can monitor data or control your instrumentation system with a Web browser ifyou use NI-488.2 in combination with NI LabVIEW, LabWindows/CVI,or Measurement Studio. Description IEEE 488 and Network Interface Details The GPIB-ENET/100 uses TCP/IP protocols to convert a computer with an Ethernet port into a GPIB Talker,Listener,and Controller.The GPIB-ENET/100 implements the full range ofGPIB controller functions. Network Details The Internet Protocol (IP) uses the Internet to route information among network nodes.The Transmission Control Protocol (TCP), used on top ofthe Internet Protocol,guarantees correct,in-sequence data between network hosts and devices. Although you commonly use TCP/IP protocols on the Internet, most TCP/IP users are not connected to the actual Internet. Individual institutions and corporations have created their own internal intranets to connect their computers,other network hosts, and devices that use TCP/IP.The regional application depicted in Figure 1 shows an example of both Internet and intranet applications. The Internet application example shows how a user on a workstation in a corporate facility can access a GPIB-ENET/100 installed in a facility at another location.Within the corporate facility,an intranet configuration connects workstations with other GPIB devices,such as printers and plotters.You can share GPIB systems throughout a building,a complex,a country,or around the world. The GPIB-ENET/100 works with both 10BaseT (10 Mb/s) and 100BaseTX (100 Mb/s) networks.It automatically detects the type of network available and communicates at the highest speed possible. Ethernet GPIB Controller •Controls IEEE 488 instruments anywhere on an Ethernet-based TCP/IP network •Up to 14 GPIB devices can be interfaced to each GPIB-ENET/100 •Shares GPIB equipment from several network hosts •Compatible with twisted pair (10BaseT or 100BaseTX) • DHCP or manual IP address assignment •Maximum GPIB transfer rates •More than 900 kbytes/s (IEEE 488.1) •More than 1.2 Mbytes/s (HS488) •GPIB-ENET/100 firmware code contained in Flash EEPROM for easy maintenance – no physical EEPROM changes required •External DC power supply • Optional rack-mount and DIN rail/wall-mount hardware Operating Systems •Windows 2000/NT/XP/Me/9x •Mac OS X,Mac OS Classic •Linux •Solaris •HP-UX •Tru64 UNIX (Digital UNIX) Recommended Software •LabVIEW •LabWindows/CVI •Measurement Studio Driver Software •NI-488.2 NI GPIB-ENET/100Ethernet GPIB Controller 2 National Instruments • Tel: (800) 433-3488•Fax: (512) 683-9300•info@ni.com•ni.com Performance The National Instruments GPIB-ENET/100 is a GPIB controller that delivers high performance by combining: • A high-performance 32-bit CPU • Fast Ethernet controller • A TNT family GPIB interface ASIC • Substantial onboard buffer RAM • Efficient firmware design Typical sustained data throughput is more than 900 kbytes/s. This performance is comparable to that ofGPIB plug-in boards.Data transfer rates can vary substantially with the NI GPIB-ENET/100 because ofthe variable network traffic and the unique operating characteristics each subnet displays. Cabling You can connect the GPIB-ENET/100 directly to 10BaseT or 100BaseTX networks using CAT 5 twisted pair Ethernet cables (see Figures 2a and 2b).Ifyou need to connect the GPIB-ENET/100 to a different type ofnetwork,such as a coax network (10Base2),you can add a converter to your setup.For example,you can place a coax-to- twisted pair converter between the GPIB-ENET/100 and the coax Ethernet tap. You can also connect a GPIB-ENET/100 controller directly to a computer Ethernet port,without using an Ethernet hub,using an Ethernet crossover cable (see Figure 2c). Network Addressing Each GPIB-ENET/100 receives a unique Ethernet hardware address at the factory. This address is a 48-bit value used to specify the source and destination of Ethernet packets.The TCP/IP protocols also require an Internet address.The Internet address is a 32-bit value used to locate a device on the network;the Internet address has no relationship to the Ethernet address. You can assign the Internet address to the GPIB-ENET/100 automatically or manually.Ifthe network uses the DHCP protocol, the GPIB-ENET/100 automatically configures its Internet address. IfDHCP is not available,you can use the NI Ethernet Device Configuration utility to assign the Internet address manually (see Figure 3a).Network parameters not assigned by DHCP are stored in nonvolatile memory.After the Internet address has been assigned, you can associate the address to a GPIB interface using Measurement and Automation Explorer (MAX),as shown in Figure 3b,and use the same programs previously written for other NI GPIB interfaces. Firmware The necessary command interpretation,IEEE 488.2 and TCP/IP protocol management,and system upkeep ofthe GPIB-ENET/100 are stored in Flash EPROM as an onboard firmware operating system.Although code is installed at the factory,you can easily upgrade the firmware by downloading new code to the GPIB-ENET/100 memory.You can download the firmware at your site with a special utility provided with NI-488.2.Firmware upgrades are instantaneous;you do not need to replace the physical EEPROM inside the GPIB-ENET/100. Internet Application The Internet GPIB-ENET/100 GPIB-ENET/100 Device 1 Device 2 Workstations, PCs Workstation, PC Device 1 Device 2 Ethernet Ethernet GPIB-ENET/100 Device 1 Intranet Application Workstations, PCs Ethernet Ethernet Figure 1. Regional Application ConfigurationEthernet GPIB Controller 3 National Instruments • Tel: (800) 433-3488•Fax: (512) 683-9300•info@ni.com•ni.com Twisted Pair Cable GPIB-ENET/100 GPIB Cable Twisted Pair Cable GPIB-ENET/100 GPIB Cable Network Hub Crossover Cable GPIB-ENET/100 GPIB Cable C. Isolated Network Using Crossover Cable A. Standard Configuration for Intranet and Internet Applications Figure 2. Network Cabling Configurations A. Detect NI Ethernet-based controllers and assign their IP addresses or host names B. Associate the IP address or host name of the GPIB-ENET/100 to a GPIB interface in Measurement & Automation Explorer Figure 3. Easy Steps to Configure Your GPIB-ENET/100 B. Isolated Network Using Desktop Hub and Standard Twisted Pair CablingEthernet GPIB Controller 4 National Instruments • Tel: (800) 433-3488•Fax: (512) 683-9300•info@ni.com•ni.com Ethernet Port 10BaseT or 100BaseTX Ethernet address set at the factory Internet address configuration by DHCP or by configuration utility IEEE 488 Compatibility Full-Function Talker, Listener, and Controller IEEE 488.1 and IEEE 488.2 compatible Handles all primary and secondary addresses Address is software selectable Performance IEEE 488 interlocked handshake......................More than 900 kbytes/s IEEE 488 non-interlocked (HS488) handshake....More than 1.1 Mbytes/s Physical Dimensions.......................................................21.0 by 12.4 by 3.7 cm (8.25 by 4.89 by 1.44 in.) Weight............................................................400 g (14.2 oz) I/O Connectors GPIB ............................................................ IEEE 488 standard 24 pin Ethernet............................................................RJ-45 Network Specifications Connection type ............................................... IEEE 802.3 compliant 10BaseT (10 Mb/s) 100BaseTX (100 Mb/s) Duplex mode....................................................Half duplex Power Requirement 9 to 30 VDC ......................................................425 mA maximum 15 VDC ............................................................ 250 mA typical Operating Environment Ambient Temperature....................................... 0 to 65 °C Relative humidity.............................................10 to 90%, noncondensing Storage Environment Ambient Temperature.......................................-40 to 100 °C Relative humidity.............................................5 to 95%, noncondensing Noise Emissions FCC Class A verified Compliance Online at ni.com/hardref.nsf Specifications Hardware GPIB-ENET/100 and NI-488.2 for Windows 2000/XP1 U.S.120 VAC.......................................................................778209-01 Swiss 220 VAC.....................................................................778209-02 Australian 240 VAC.............................................................778209-03 Universal Euro 240 VAC.....................................................778209-04 North American 240 VAC..................................................778209-05 United Kingdom 240 VAC..................................................778209-06 1 NI-488.2 for Windows 2000/XP available in English,Japanese,Korean,simplified Chinese,and traditional Chinese. Software NI-488.2 Windows NT.......................................................................778220-02 Windows Me/9x..................................................................778258-02 Linux....................................................................................778259-02 Mac OS X............................................................................778251-02 Mac OS Classic....................................................................778257-02 Solaris..................................................................................778256-02 HP-UX.................................................................................778377-02 Tru64 UNIX........................................................................778378-02 Contact NI for availability with other OSs. Cables GPIB X2 cable (double shielded) 1 m...................................................................................763061-01 2 m...................................................................................763061-02 4 m...................................................................................763061-03 8 m...................................................................................763061-04 Ethernet CAT5 twisted-pair 10/100BaseT cable (E1 cable) 1 m...................................................................................182219-01 5 m...................................................................................182219-05 10 m.................................................................................182219-10 CAT5 twisted-pair crossover cable (E4 cable) 1 m...................................................................................187375-01 5 m...................................................................................187375-05 10 m.................................................................................187375-10 CAT5 shielded twisted-pair 10/100 BaseT cable (E5 cable) 1 m...................................................................................189174-01 5 m...................................................................................189174-05 10 m.................................................................................189174-10 Additional Hardware Options Rack-mount kit (single/dual case)..........................................187322-02 DIN-rail/wall-mount kit (single unit)....................................777972-01 BUYNOW! For complete product specifications,pricing,and accessory information,call (800) 813-3693 (U.S.only) or go to ni.com/gpib. Ordering InformationNI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance.We offer services and service levels to meet customer requirements in research, design,validation,and manufacturing. Visit ni.com/services. Training and Certification NI training is the fastest,most certain route to productivity with our products.NI training can shorten your learning curve,save development time,and reduce maintenance costs over the application life cycle.We schedule instructor-led courses in cities worldwide,or we can hold a course at your facility.We also offer a professional certification program that identifies individuals who have high levels ofskill and knowledge on using NI products. Visit ni.com/training. Professional Services Our Professional Services Team is comprised ofNI applications engineers,NI Consulting Services,and a worldwide NI Alliance Partner Program ofmore than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications.For information about special pricing and services for OEM customers, visit ni.com/oem. Local Sales and Technical Support In offices worldwide,our staffis local to the country,giving you access to engineers who speak your language.NI delivers industry- leading technical support through online knowledge bases,our applications engineers,and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support.Visit ni.com/ssp. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI™ combination systems right out ofthe box.Trained NI technicians install the software and hardware and configure the system to your specifications.NI extends the standard warranty by one year on hardware components (controllers,chassis, modules) purchased with FIS.To use FIS,simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements.We provide manual calibration procedures, services to recalibrate your products,and automated calibration software specifically designed for use by metrology laboratories.Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products.Express repair and advance replacement services are also available.We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. SERVICE NEEDS © 2004 National Instruments Corporation. All rights reserved. LabVIEW, CVI, Measurement Studio, NIAlliance Partner, SCXI, and ni.com are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. National Instruments • Tel: (512) 683-0100 • Fax: (512) 683-9300 • info@ni.com ni.com • (800) 433-3488 |
|
文件下载(右键文件另存为) |